Osburn OB01801 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Pro domov Osburn OB01801. Osburn OB01801 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45058A
Printed in Canada 12-06-2015
OWNER`S MANUAL
1800 INSERT
(OB01801 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD INSERT
Verified and tested following
ULC S627 and UL 1482 Standards by an
accredited laboratory
Manufactured by: STOVE BUILDER INTERNATIONAL INC.
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
After-sale service: 418-908-8002 E-mail: tech@sbi-international.com
www.osburn-mfg.com
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - 1800 INSERT

READ AND KEEP THIS MANUAL FOR REFERENCE 45058A Printed in Canada 12-06-2015 OWNER`S MANUAL 1800 INSERT (OB01801 model) US ENVIRONMENTAL PROT

Strany 2 - INTRODUCTION

/10 2.6 Positioning the unit In addition to ensuring compliance of the masonry fireplace hearth extension (see Compliance of the masonry fireplace i

Strany 3 - TABLE OF CONTENTS

/11If a non-combustible material floor protection needs to be added in front and level with the hearth extension masonry fireplace (s

Strany 4

/12The use of an R value is convenient when more than one material is going to be used in the hearth extension to cover the combustible surfa

Strany 5

/13Thermal characteristics of common floor protection materials* MATERIAL CONDUCTIVITY (k) PER INCH RESISTANCE (R) PER INCH THICKNESS Micore® 160

Strany 6

/14 MINIMUM MASONRY OPENING J 20" (508 mm) K 23 3/8" (594 mm) L 14 5/8" (371 mm) CLEARANCES F 17" (432 mm) G 10" (254

Strany 7 - Section 2.0 Installation

/152.8 Connector installation A masonry flue connector may provide acceptable performance (Figure 2.8a); however, we recommend the use of a chimney

Strany 8

/162.8.1 Chimney liner installation To install of the chimney liner, the preferred methods are those found in Section 2.8.1.1. Use a liner offset ad

Strany 9 - SHELF POSITIONING

/172.8.1.2 If the chimney liner does not align with the insert’s flue outlet: You can get a liner offset adapter (AC01370), sold separately. If you

Strany 10

/182.9 Air control plate, faceplate and fan Assembly Instructions 1. Place the faceplate panels with the finished side down on a flat, soft, non-ab

Strany 11

/19 Figure 2.9c Figure 2.9d Figure 2.9e 7. Fan is already attached to the unit at the factory with two tie str

Strany 12

/2INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase

Strany 13

/208. Cooktop is installed at the factory. Shipping screw must be removed before installation of faceplates. (Figure 2..9f) 9. Install faceplate (

Strany 14

/21Section 3.0 Operation 3.1 Safety Information 1. This insert is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or

Strany 15

/2210. Never operate the insert with the door open, or cracked slightly open, except briefly during the lighting operation, and during refuelling. L

Strany 16

/23Common Heating Values of Cordwood Hardwoods Million Btu/Cord Softwoods Million Btu/Cord Birch 23.6 Douglas Fir 20.6 White Oak 28.3 Hemloc

Strany 17

/24the door. 6. Ideally the large kindling should be burned until a thick bed of red embers is obtained. At that point, add cordwood fuel and conti

Strany 18

/253.5 Maintaining The Fire Your Osburn insert will work best if a thick bed of hot embers is maintained in the bottom of the firebox, and a minimum

Strany 19

/263.6 Fan Operation 1. Allow the insert to reach operating temperature (approximately one hour), before turning on the fan, since increased ai

Strany 20

/27Section 4.0 Maintenance 4.1 Care And Cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to

Strany 21 - Section 3.0 Operation

/28CAUTION: OPERATION OF YOUR OSBURN 1800 WITHOUT THE BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY. Conta

Strany 22 - ORDWOOD

/294.4 Baffle Installation and Brick Notes: 1. Stack the baffle boards (A) on top of the vermiculite boards (B) as shown in figure 4.4a . Figure 4

Strany 23

/3TABLE OF CONTENTS INTRODUCTION...

Strany 24

/303. Install the baffle support/extension (H) ensuring that it fits between the front risers and hold it in place. Install the front secondary air

Strany 25

/31All firebrick and duraboard baffles must be properly in place for correct burning operation. Have any damaged firebricks replaced. Check the fireb

Strany 26

/324.5 Secondary Air Tube Replacement (see Figure 4.5) 1. Remove cotter pin at LH end of tube. 2. Slide tube to right and lower tube end below LH p

Strany 27 - Section 4.0 Maintenance

/334.6 Fan Maintenance & Care Clean the fan air inlet louvres and squirrel cage impeller regularly. The fan should be kept clean and dust free.

Strany 28

/34Section 5.0 Troubleshooting Symptom Possible Cause Corrective Action I Smoke in room 1. Down draft 1. Upgrade chimney 2. Chim

Strany 29

/35Section 6.0 Specifications Fuel Type Dry cordwood Test Standards ULC S628 (CSA B366.2) & UL 1482 residential. Maximum re

Strany 30

/36OSBURN LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transfe

Strany 31

/4OUTSIDE DIMENSIONS

Strany 32

/5Section 1.0 Pre-Installation Requirements This unit is designed for safe operation. Altering or modifying the unit, or installation, without p

Strany 33 - WARRANTY"

/66. OPENING SIZE: Refer to “Suitable Fireplace Dimensions” for suitable size fireplace openings. NOTE: A METAL TAG IS PROVIDED AN

Strany 34

/7Section 2.0 Installation 2.1 Safety information NOTE: THIS APPLIANCE IS NOT RECOMMENDED FOR USE IN A HOME IF AN OCCUPANT HAS ANY RESPIRATORY OR

Strany 35 - Section 6.0 Specifications

/82.2 Installation instructions Inspect the masonry fireplace according to the safety information and fireplace requirements and have it cleaned and

Strany 36

/92.4 The masonry fireplace's draft control system If the fireplace's draft control system is to remain in the masonry fireplace, it must

Komentáře k této Příručce

Žádné komentáře