Stratford Fireplace Installation and Operation Manual
86 _____________________________________________________________________
Note: Only remove the knock-out that will be connected to the fresh air inlet.
The fresh air intake kit may be installed on three different places on the fireplace.
1- On the right side of the appliance (most common).
2- On the right side, at the back of the appliance.
3- On the right side under the appliance.
(1) Using a Philips screwdriver,
remove the four screws holding
the rectangular plate (A) on the
right of the fireplace jacket. If
the location 2 or 3 has been
chosen, use pliers to remove the
knock-out.
(2) Secure the fresh air intake kit
adapter (B) on the fireplace
jacket using the 4 screws
provided with the kit.